Heating, Cooling and Relative Humidity Thermostat, Almond Faceplate

Get Custom Programming from 4TEC

Price: $790.00
    Quantity:
    Availability: In Stock
    Usually ships In 24 - 48 hours

    Item #: CHV-THSTATA

    Description

    The CHV-THSTAT is a versatile heating and cooling thermostat with integrated humidistat designed for one- and two-stage control of forced air, radiant, and heat pump HVAC systems. Although functional as a standalone thermostat, the CHV-THSTAT delivers greatly enhanced functionality as part of a complete automation system from Crestron Available in white, black, or almond, the stylish wall mount design is a complement to any decor.

    Specifications

    Measurement Range
    • Indoor Temperature 0° to 110°F (-18° to 43°C)
    • Outdoor Temperature -40 to 170 F (-40 to 77 C)[1]
    • Humidity 0% to 100% RH
    Temperature Tolerance
    • Over Full Range 1F (0.5C)
    • At Room Temperatures 1F (+0.1/-0.4C)
    Humidity Tolerance
    • 5%
    Setpoint Range
    • Auto Setpoint 38° to 99°F (3° to 37°C)
    • Heat only Setpoint 38° to 89°F (3° to 32°C)
    • Cool only Setpoint 59° to 99°F (15° to 37°C)
    • Humidity Setpoint 5% to 70% RH[2]
    Relay Rating
    • 1 Amp @ 40 Volts DC or 24 Volts AC (nominal)
    Power Requirements
    • 24V 2 Watts (0.083 Amps) @ 24 Volts AC, supplied by heating or cooling system
    • Cresnet Power Usage <1 Watts (<0.05 Amps @ 24 Volts DC), required for Cresnet® communication only
    Buttons
    • MODE Accesses user controls - system mode, fan mode, humidifier, Crestron® system, and global update
    • VIEW Accesses humidity reading, outdoor temperature reading[1], system messages, and remote functions
    • UP Selects user modes and increments selection in setup modes
    • DOWN Selects user modes and decrements selection in setup modes
    Display
    • Type Transflective LCD, backlit
    • Size 2.75 in (6.99 cm)
    • Resolution 128 x 64
    • Viewing Angle 50° horizontal (@0° vertical), 50° vertical (@0° horizontal)
    • Displays current indoor temperature and relative humidity, outdoor temperature and relative humidity[2], setpoints, activity, function, Cresnet system information, internal relay status, setup menus, and control system messages.
    Connectors
    • HVAC (2) 9-position terminal blocks comprising the following:
    • Power Connections (Required):
    • 24 (C): 24 VAC common terminal supplies remote 24 VAC power to thermostat;
    • 24 (R): 24 VAC reference terminal – Can be Connected to RH or RC by P4 jumper setting, or tied directly to power source
    • HVAC Control Connections (System Dependent):
    • HUM: Energized to RHU during humidity call;
    • RHU: Reference for humidifier;
    • RH: Reference Heat – Used for calls to heating system;
    • RC: Reference Cool – Used for calls to cooling system;
    • G: Fan – Energized to RC during call for fan;
    • Y/Y1: Compressor (stage one) – Energized to RC when compressor (or first stage) is run;
    • Y2: Compressor (stage two) – Energized to RC on two-stage systems on call for second stage;
    • O: Changeover control – Energized to RC during cooling modes;
    • B: Energized to RC during non-cooling modes;
    • W/W1: Heat (single stage)/heat (stage one) – Energized to RH during a call for heat in heat/cool systems or aux heat in heat pump systems;
    • W2: Heat (stage two) – Energized to RH during a call for second stage heat in heat/cool systems
    • Remote Sensing Connections (Optional):
    • RSR: Remote Sensor Returns – Common sensor terminal;
    • RS1: Remote Sensor terminal – Connect the sensor from RS1 to RSR;
    • RS2: Remote Sensor terminal – Connect the sensor from RS2 to RSR
    • NETWORK (1) 4-position terminal block;
    • Cresnet slave port, connects to Cresnet control network
    Enclosure
    • Plastic, surface-mountable to the front of a horizontally oriented 1-gang electrical box
    Dimensions
    • Height 3.75 in (96 mm)
    • Width 5.00 in (127 mm)
    • Depth 1.04 in (27 mm)
    Weight
    • 5.80 oz (165 g)

    Additional Information

    Measurement Range
    • Indoor Temperature 0° to 110°F (-18° to 43°C)
    • Outdoor Temperature -40 to 170 F (-40 to 77 C)[1]
    • Humidity 0% to 100% RH
    Temperature Tolerance
    • Over Full Range 1F (0.5C)
    • At Room Temperatures 1F (+0.1/-0.4C)
    Humidity Tolerance
    • 5%
    Setpoint Range
    • Auto Setpoint 38° to 99°F (3° to 37°C)
    • Heat only Setpoint 38° to 89°F (3° to 32°C)
    • Cool only Setpoint 59° to 99°F (15° to 37°C)
    • Humidity Setpoint 5% to 70% RH[2]
    Relay Rating
    • 1 Amp @ 40 Volts DC or 24 Volts AC (nominal)
    Power Requirements
    • 24V 2 Watts (0.083 Amps) @ 24 Volts AC, supplied by heating or cooling system
    • Cresnet Power Usage <1 Watts (<0.05 Amps @ 24 Volts DC), required for Cresnet® communication only
    Buttons
    • MODE Accesses user controls - system mode, fan mode, humidifier, Crestron® system, and global update
    • VIEW Accesses humidity reading, outdoor temperature reading[1], system messages, and remote functions
    • UP Selects user modes and increments selection in setup modes
    • DOWN Selects user modes and decrements selection in setup modes
    Display
    • Type Transflective LCD, backlit
    • Size 2.75 in (6.99 cm)
    • Resolution 128 x 64
    • Viewing Angle 50° horizontal (@0° vertical), 50° vertical (@0° horizontal)
    • Displays current indoor temperature and relative humidity, outdoor temperature and relative humidity[2], setpoints, activity, function, Cresnet system information, internal relay status, setup menus, and control system messages.
    Connectors
    • HVAC (2) 9-position terminal blocks comprising the following:
    • Power Connections (Required):
    • 24 (C): 24 VAC common terminal supplies remote 24 VAC power to thermostat;
    • 24 (R): 24 VAC reference terminal – Can be Connected to RH or RC by P4 jumper setting, or tied directly to power source
    • HVAC Control Connections (System Dependent):
    • HUM: Energized to RHU during humidity call;
    • RHU: Reference for humidifier;
    • RH: Reference Heat – Used for calls to heating system;
    • RC: Reference Cool – Used for calls to cooling system;
    • G: Fan – Energized to RC during call for fan;
    • Y/Y1: Compressor (stage one) – Energized to RC when compressor (or first stage) is run;
    • Y2: Compressor (stage two) – Energized to RC on two-stage systems on call for second stage;
    • O: Changeover control – Energized to RC during cooling modes;
    • B: Energized to RC during non-cooling modes;
    • W/W1: Heat (single stage)/heat (stage one) – Energized to RH during a call for heat in heat/cool systems or aux heat in heat pump systems;
    • W2: Heat (stage two) – Energized to RH during a call for second stage heat in heat/cool systems
    • Remote Sensing Connections (Optional):
    • RSR: Remote Sensor Returns – Common sensor terminal;
    • RS1: Remote Sensor terminal – Connect the sensor from RS1 to RSR;
    • RS2: Remote Sensor terminal – Connect the sensor from RS2 to RSR
    • NETWORK (1) 4-position terminal block;
    • Cresnet slave port, connects to Cresnet control network
    Enclosure
    • Plastic, surface-mountable to the front of a horizontally oriented 1-gang electrical box
    Dimensions
    • Height 3.75 in (96 mm)
    • Width 5.00 in (127 mm)
    • Depth 1.04 in (27 mm)
    Weight
    • 5.80 oz (165 g)