Spotlight!
Heating, Cooling and Relative Humidity Thermostat, Black Faceplate

Get Custom Programming from 4TEC

Price: $790.00
Quantity:
Availability: In Stock
Usually ships In 24 - 48 hours

Item #: CHV-THSTATB

Description

The CHV-THSTAT is a versatile heating and cooling thermostat with integrated humidistat designed for one- and two-stage control of forced air, radiant, and heat pump HVAC systems. Although functional as a standalone thermostat, the CHV-THSTAT delivers greatly enhanced functionality as part of a complete automation system from Crestron Available in white, black, or almond, the stylish wall mount design is a complement to any decor.

Specifications

Measurement Range
  • Indoor Temperature 0° to 110°F (-18° to 43°C)
  • Outdoor Temperature -40 to 170 F (-40 to 77 C)[1]
  • Humidity 0% to 100% RH
Temperature Tolerance
  • Over Full Range 1F (0.5C)
  • At Room Temperatures 1F (+0.1/-0.4C)
Humidity Tolerance
  • 5%
Setpoint Range
  • Auto Setpoint 38° to 99°F (3° to 37°C)
  • Heat only Setpoint 38° to 89°F (3° to 32°C)
  • Cool only Setpoint 59° to 99°F (15° to 37°C)
  • Humidity Setpoint 5% to 70% RH[2]
Relay Rating
  • 1 Amp @ 40 Volts DC or 24 Volts AC (nominal)
Power Requirements
  • 24V 2 Watts (0.083 Amps) @ 24 Volts AC, supplied by heating or cooling system
  • Cresnet Power Usage <1 Watts (<0.05 Amps @ 24 Volts DC), required for Cresnet® communication only
Buttons
  • MODE Accesses user controls - system mode, fan mode, humidifier, Crestron® system, and global update
  • VIEW Accesses humidity reading, outdoor temperature reading[1], system messages, and remote functions
  • UP Selects user modes and increments selection in setup modes
  • DOWN Selects user modes and decrements selection in setup modes
Display
  • Type Transflective LCD, backlit
  • Size 2.75 in (6.99 cm)
  • Resolution 128 x 64
  • Viewing Angle 50° horizontal (@0° vertical), 50° vertical (@0° horizontal)
  • Displays current indoor temperature and relative humidity, outdoor temperature and relative humidity[2], setpoints, activity, function, Cresnet system information, internal relay status, setup menus, and control system messages.
Connectors
  • HVAC (2) 9-position terminal blocks comprising the following:
  • Power Connections (Required):
  • 24 (C): 24 VAC common terminal supplies remote 24 VAC power to thermostat;
  • 24 (R): 24 VAC reference terminal – Can be Connected to RH or RC by P4 jumper setting, or tied directly to power source
  • HVAC Control Connections (System Dependent):
  • HUM: Energized to RHU during humidity call;
  • RHU: Reference for humidifier;
  • RH: Reference Heat – Used for calls to heating system;
  • RC: Reference Cool – Used for calls to cooling system;
  • G: Fan – Energized to RC during call for fan;
  • Y/Y1: Compressor (stage one) – Energized to RC when compressor (or first stage) is run;
  • Y2: Compressor (stage two) – Energized to RC on two-stage systems on call for second stage;
  • O: Changeover control – Energized to RC during cooling modes;
  • B: Energized to RC during non-cooling modes;
  • W/W1: Heat (single stage)/heat (stage one) – Energized to RH during a call for heat in heat/cool systems or aux heat in heat pump systems;
  • W2: Heat (stage two) – Energized to RH during a call for second stage heat in heat/cool systems
  • Remote Sensing Connections (Optional):
  • RSR: Remote Sensor Returns – Common sensor terminal;
  • RS1: Remote Sensor terminal – Connect the sensor from RS1 to RSR;
  • RS2: Remote Sensor terminal – Connect the sensor from RS2 to RSR
  • NETWORK (1) 4-position terminal block;
  • Cresnet slave port, connects to Cresnet control network
Enclosure
  • Plastic, surface-mountable to the front of a horizontally oriented 1-gang electrical box
Dimensions
  • Height 3.75 in (96 mm)
  • Width 5.00 in (127 mm)
  • Depth 1.04 in (27 mm)
Weight
  • 5.80 oz (165 g)

Additional Information

Measurement Range
  • Indoor Temperature 0° to 110°F (-18° to 43°C)
  • Outdoor Temperature -40 to 170 F (-40 to 77 C)[1]
  • Humidity 0% to 100% RH
Temperature Tolerance
  • Over Full Range 1F (0.5C)
  • At Room Temperatures 1F (+0.1/-0.4C)
Humidity Tolerance
  • 5%
Setpoint Range
  • Auto Setpoint 38° to 99°F (3° to 37°C)
  • Heat only Setpoint 38° to 89°F (3° to 32°C)
  • Cool only Setpoint 59° to 99°F (15° to 37°C)
  • Humidity Setpoint 5% to 70% RH[2]
Relay Rating
  • 1 Amp @ 40 Volts DC or 24 Volts AC (nominal)
Power Requirements
  • 24V 2 Watts (0.083 Amps) @ 24 Volts AC, supplied by heating or cooling system
  • Cresnet Power Usage <1 Watts (<0.05 Amps @ 24 Volts DC), required for Cresnet® communication only
Buttons
  • MODE Accesses user controls - system mode, fan mode, humidifier, Crestron® system, and global update
  • VIEW Accesses humidity reading, outdoor temperature reading[1], system messages, and remote functions
  • UP Selects user modes and increments selection in setup modes
  • DOWN Selects user modes and decrements selection in setup modes
Display
  • Type Transflective LCD, backlit
  • Size 2.75 in (6.99 cm)
  • Resolution 128 x 64
  • Viewing Angle 50° horizontal (@0° vertical), 50° vertical (@0° horizontal)
  • Displays current indoor temperature and relative humidity, outdoor temperature and relative humidity[2], setpoints, activity, function, Cresnet system information, internal relay status, setup menus, and control system messages.
Connectors
  • HVAC (2) 9-position terminal blocks comprising the following:
  • Power Connections (Required):
  • 24 (C): 24 VAC common terminal supplies remote 24 VAC power to thermostat;
  • 24 (R): 24 VAC reference terminal – Can be Connected to RH or RC by P4 jumper setting, or tied directly to power source
  • HVAC Control Connections (System Dependent):
  • HUM: Energized to RHU during humidity call;
  • RHU: Reference for humidifier;
  • RH: Reference Heat – Used for calls to heating system;
  • RC: Reference Cool – Used for calls to cooling system;
  • G: Fan – Energized to RC during call for fan;
  • Y/Y1: Compressor (stage one) – Energized to RC when compressor (or first stage) is run;
  • Y2: Compressor (stage two) – Energized to RC on two-stage systems on call for second stage;
  • O: Changeover control – Energized to RC during cooling modes;
  • B: Energized to RC during non-cooling modes;
  • W/W1: Heat (single stage)/heat (stage one) – Energized to RH during a call for heat in heat/cool systems or aux heat in heat pump systems;
  • W2: Heat (stage two) – Energized to RH during a call for second stage heat in heat/cool systems
  • Remote Sensing Connections (Optional):
  • RSR: Remote Sensor Returns – Common sensor terminal;
  • RS1: Remote Sensor terminal – Connect the sensor from RS1 to RSR;
  • RS2: Remote Sensor terminal – Connect the sensor from RS2 to RSR
  • NETWORK (1) 4-position terminal block;
  • Cresnet slave port, connects to Cresnet control network
Enclosure
  • Plastic, surface-mountable to the front of a horizontally oriented 1-gang electrical box
Dimensions
  • Height 3.75 in (96 mm)
  • Width 5.00 in (127 mm)
  • Depth 1.04 in (27 mm)
Weight
  • 5.80 oz (165 g)