    The CHV-TSTAT is a versatile heating and cooling thermostat for one- and two-stage control of forced air, radiant, and heat pump HVAC systems. Relative humidity capability can be added through an external remote humidity sensor (sold separately). Although functional as a standalone thermostat, the CHV-TSTAT delivers greatly enhanced functionality as part of a complete home automation system from Crestron Available in white, black, or almond, the stylish wall mount design is a complement to any decor.

    The large backlit LCD display, navigable using four simple pushbuttons, provides easy access to indoor and outdoor temperature and humidity readings, set point adjustments, system mode and fan status indicators, and setup menus. Climate control features include separate heating, cooling, and humidity set points with optional automatic changeover between heating and cooling modes. Adjustable anticipators prevent overshooting the set temperature, and continuous fan operation can be selected when needed for increased circulation.

    Automation System Integration

    Multiple Crestron thermostats may be networked via Cresnet to any 3-Series control system, including the DIN-AP3, enabling global temperature and humidity adjustment from any thermostat. Automation functions such as lighting, motorized blinds, or lawn sprinklers can be accessed through two custom remote function pages, and customized text messages can be sent to the LCD display to provide maintenance reminders and other alerts.

    Its connection to the control system also allows for full control and scheduling of the CHV-TSTAT from touch screens and computers throughout the home, and supports extensive Flexibility for integration with other devices and systems. In the event that communication with the control system is disrupted for any reason, the CHV-TSTAT will remain operable to control the HVAC system.

    Remote Sensors

    Optional remote temperature and humidity sensors can be Connected to the CHV-TSTAT for enhanced Flexibility and optimized performance. Climate can be regulated according to an average of multiple sensors, or the built-in sensors can be disabled entirely to allow the CHV-TSTAT to be installed out of view. Outdoor climate can also be monitored, enabling outdoor low-temperature compensation to prevent condensation on windows during cold weather. The CHV-TSTAT accepts up to four remote temperature sensors, two remote temp/humidity sensors, or a combination of one temp/humidity and two temperature sensors.

    Measurement Range

    • Indoor Temperature 0 to 110F (-18 to 43C)
    • Outdoor Temperature -40 to 170F (-40 to 77C)[1]
    • Humidity 0% to 100% RH[1]

    Temperature Tolerance

    • Over Full Range 1F (0.5C)
    • At Room Temperatures 1F (+0.1/-0.4C)

    Set point Range

    • Auto Set point 38 to 99F (3 to 37C)
    • Heat only Set point 38 to 89F (3 to 32C)
    • Cool only Set point 59 to 99F (15 to 37C), or 38 to 99F (3 to 37C) extended cool mode enabled
    • Humidity Set point 5% to 70% RH[1]

    Relay Rating

    • 1 Amp @ 40 Volts DC or 24 Volts AC (nominal)

    Power Requirements

    • 24V 2 Watts (0.083 Amps) @ 24 Volts AC, supplied by heating or cooling system
    • Cresnet Power Usage <1 Watts (<0.05 Amps @ 24 Volts DC), required for Cresnet communication only

    Buttons

    • MODE Accesses user controls - system mode, fan mode, humidifier[1], Crestron system, and global update
    • VIEW Accesses humidity reading[1], outdoor temperature reading[1], system messages, and remote functions
    • UP Selects user modes and increments selection in setup modes
    • DOWN Selects user modes and decrements selection in setup modes

    Display

    • Type Transflective LCD, backlit
    • Size 2.75 in (6.99 cm)
    • Resolution 128 x 64
    • Viewing Angle 50 horizontal (@0 vertical), 50 vertical (@0 horizontal)
    • Displays current indoor temperature and relative humidity[1], outdoor temperature and relative humidity[1], set points, activity, function, Cresnet system information, internal relay status, setup menus, and control system messages.

    Connectors

    • HVAC (2) 9-position terminal blocks comprising the following: Power Connections (Required):
    • 24 (C): 24V AC common terminal supplies remote 24V AC power to thermostat;
    • 24 (R): 24V AC reference terminal Can be Connected to RH or RC by P4 jumper setting, or tied directly to power source HVAC Control Connections (System Dependent):
    • HUM: Energized to RHU during humidity call;
    • RHU: Reference for humidifier;
    • RH: Reference Heat Used for calls to heating system;
    • RC: Reference Cool Used for calls to cooling system;
    • G: Fan Energized to RC during call for fan;
    • Y/Y1: Compressor (stage one) Energized to RC when compressor (or first stage) is run;
    • Y2: Compressor (stage two) Energized to RC on two-stage systems on call for second stage;
    • O: Changeover control Energized to RC during cooling modes;
    • B: Energized to RC during non-cooling modes;
    • W/W1: Heat (single stage)/heat (stage one) Energized to RH during a call for heat in heat/cool systems or aux heat in heat pump systems;
    • W2: Heat (stage two) Energized to RH during a call for second stage heat in heat/cool systems
      • Remote Sensing Connections (Optional):
      • RSR: Remote Sensor Returns Common sensor terminal;
      • RS1: Remote Sensor terminal Connect the sensor from RS1 to RSR;
      • RS2: Remote Sensor terminal Connect the sensor from RS2 to RSR
      • NETWORK (1) 4-position terminal block;
      • Cresnet slave port, connects to Cresnet control network

      Enclosure

      • Plastic, surface-mountable to the front of a horizontally oriented 1-gang electrical box

      Dimensions

      • Height 3.75 in (96 mm)
      • Width 5.00 in (127 mm)
      • Depth 1.04 in (27 mm)

      Weight

      • 5.80 oz (165 g)

      Specifications

      Download Technical Specifications

      CHV-TSTAT

      Additional Information

      Key Features

      • Wall mount heat/cool thermostat for one- and two-stage control of forced air, radiant and heat pump HVAC systems
      • Multiple Crestron thermostats may be networked via Cresnet
      • Supports remote humidity sensors and outdoor temperature sensors
      • Backlit LCD display
      • Front panel buttons for setup, configuring, and temperature and humidity adjustments[1]
      • Available in white, black, or almond finish