infiNET EX® Thermostat, Fan Coil Unit, White Textured

  • Easy to install wall-mount thermostat
  • Connects wirelessly to a control system via infiNET EX®
  • Saves on energy costs with advanced programming abilities
Price: $575.00
    Quantity:
    Availability: In Stock
    Usually ships In 24 - 48 hours

    Item #: CHV-TSTATEX-FCU-W-T

    Description

    The CHV-TSTATEX is a wireless thermostat featuring infiNET EX® technology. The CHV-TSTATEX installs just like a conventional thermostat because no extra wires are needed to connect to the control system. Although functional as a standalone thermostat, the CHV-TSTATEX delivers enhanced functionality as part of a complete Crestron® automation system. Integrating HVAC with a Crestron system can help lower energy bills and increase user friendliness.

    The CHV-TSTATEX is designed for one- or two-stage heating and one- or two-stage cooling control of baseboard, forced air, heat pump[1], and dual-fuel heat pump[1] HVAC systems. The large backlit LCD display provides a clear view of temperature, set point, system mode, fan mode, system status, and setup functions. Climate control features include separate heating and cooling set points, and adjustable anticipators to prevent overshooting the desired temperature. Continuous fan operation can be selected when needed for increased circulation.

    Fan Coil Unit Support

    The CHV-TSTATEX-FCU model of the infiNET EX thermostat provides the functionality of controlling fan coil units[2]. Aesthetically identical to the base model, the CHV-TSTATEX-FCU has custom firmware, display programming and terminal labels designed for three-speed fan applications. The CHV-TSTATEX-FCU supports on/off control of the valves and the fan in four-pipe fan coil applications, eliminating the need for an additional device dedicated to controlling the fan coil unit itself.

    infiNET EX Communications

    Ultra-reliable infiNET EX wireless technology provides steadfast two-way RF communications throughout a residential or commercial structure without the need for physical control wiring. Employing a 2.4 GHz mesh network topology, each infiNET EX device functions as an expander, passing command signals through to every other infiNET EX device within range (approximately 150 feet or 46 meters indoors), ensuring that every command reaches its intended destination without disruption[3].

    The CHV-TSTATEX communicates with a Crestron control system via an infiNET EX Wireless Gateway (model CEN-RFGW-EX, DIN-AP3MEX, or MC3[4]). Up to 100 infiNET EX devices may coexist on a single wireless network, and every non-battery-powered device that is added to the network effectively increases the range and stability of the entire network by providing multiple redundant signal paths[3]. Built-in Dynamic Frequency Allocation continuously monitors RF conditions, automatically selecting the clearest channel to prevent interference from neighboring networks, cordless phones, and microwaves.

    Automation System Integration

    The wireless connection to the control system allows the functions of the CHV-TSTATEX to be controlled from touch screens, keypads, wireless remotes, computers, or even a mobile device. It supports unlimited flexibility for remote control, scheduling, and integration with other devices and systems. In the event that communication with the control system is disrupted for any reason, the CHV-TSTATEX will remain operable to control the HVAC system.

    Easy Installation

    Because no control wires are required, the CHV-TSTATEX can be installed just like any conventional thermostat. To simplify installation, physical switches are provided for the most critical configuration options, including heat/cool type, heat pump behavior, power settings, number of heating/cooling stages, and fan options. These settings allow HVAC contractors to install and test the thermostats prior to the appearance of a Crestron system integrator.

    Remote Sensors

    Optional remote temperature sensors can be connected to the CHV-TSTATEX for enhanced flexibility and optimized performance. Climate can be regulated according to an average of multiple sensors, or the built-in sensors can be disabled entirely to allow the CHV-TSTATEX to be installed out of view. For heat pump-type systems, outdoor temperature can be monitored to optimize system performance. Compatible sensors include the CHV-RTS and the CHV-RSS.

    Key Features
    • Wall mount heat/cool thermostat for baseboard, forced air, and heat pump[1] HVAC systems
    • Crestron system integration via infiNET EX® wireless network
    • Saves on energy costs with advanced programming abilities
    • Supports two remote temperature sensors
    • Fail-safe mode allows operation in event of control system failure
    • Backlit LCD display
    • Fan coil unit control[2] (CHV-TSTATEX-FCU model only)
    • Available in white, black, or almond finish
    1. Heat pump systems require an outdoor temperature sensor; contact Crestron for additional design assistance.
    2. Four-pipe fan coil units are supported.
    3. Any infiNET EX device that provides expander functionality will effectively extend the range of the wireless network beyond the initial range of the gateway. Battery-powered infiNET EX devices do not provide expander functionality. To achieve expander functionality, the CHV-TSTATEX must be connected to a 24-Volt power source. Wireless networks composed predominantly of battery-powered devices may need additional infiNET EX expanders, such as the CLW-EXPEX or GLA-EXPEX (sold separately), or other non-battery-powered infiNET EX devices to ensure proper functionality of the network and battery life for the devices. Refer to the Best Practices for Installation and Setup of Crestron RF Products, Doc. #6689 for complete system design guidelines, or contact Crestron True Blue Support for further assistance.
    4. Item(s) sold separately.

    Specifications

    Wireless
    RF TransceiverinfiNET EX® 2-way RF, 2.4 GHz ISM Channels 11-26 (2400 to 2483.5 MHz), default channel 15; IEEE 802.15.4 compliant
    Range (typical)150 ft (46 m) indoor, 250 ft (76 m) outdoor to nearest mesh network device(s); subject to site-specific conditions and individual device capabilities[3]
    GatewayRequires an infiNET EX gateway[4]
    Connectors
    HVAC

    CHV-TSTATEX Model:
    7 terminal blocks comprising the following (top row, listed left to right):
    RS2: Remote sensor 2 (outdoor)
    RS1: Remote sensor 1 (indoor)
    RSR: Remote sensor return
    RSR: Remote sensor return (duplicated for easier wiring)
    W2: Heat, second stage
    W1: Heat, first stage
    RH: Heat return

    7 terminal blocks comprising the following (bottom row, listed left to right)
    B: Auto changeover (inverted); switched to RC during heat calls
    O: Auto changeover; switched to RC during cool calls
    G: Fan
    Y2: Cool, second stage
    Y1: Cool, first stage
    RC: Cool return
    C: 24 VAC common

    CHV-TSTATEX-FCU Model:
    7 terminal blocks comprising the following (top row, listed left to right):
    RS2: Remote sensor 2 (outdoor)
    RS1: Remote sensor 1 (indoor)
    RSR: Remote sensor return
    RSR: Remote sensor return (duplicated for easier wiring)
    N/C: Unused
    W: Heat
    N/C: Unused

    7 terminal blocks comprising the following (bottom row, listed left to right):
    24C: 24V supply
    R: 24V return
    Y: Cool
    N/C: Unused
    GH: Fan high
    GM: Fan medium
    GL: Fan low

    Buttons
    MODECycles through available System Modes: OFF, HEAT, AUX HEAT ONLY (for heatpump or dual-fuel systems only), and COOL
    FANToggles fan setting between FAN AUTO and FAN ON
    RAISERaises the set point
    LOWERLowers the set point
    HOLD (combination)Pressing MODE and FAN buttons simultaneously enters/exits HOLD mode
    SETUP (combination)Holding the FAN button, then pressing the RAISE and LOWER buttons simultaneously for 5 seconds enters SETUP mode; pressing mode button advances to next setup parameter/function; pressing RAISE or LOWER adjusts value of current setup parameter or executes current setup function; pressing FAN button exits SETUP mode
    Display
    TypeBacklit LCD with (2) large 7-segment digits, (2) small 7-segment digits, (14) dedicated symbols;
    Displays ambient temperature, set point, system mode, fan setting, call activity, low battery, RF or control system communication errors, firmware download progress, setup parameter/function and value
    Measurement Range
    Ambient Temperature-10° to 110°F (-23° to 43°C)
    Display Limits-9° to 99°F (-9° to 43°C)
    Temperature Tolerance
    Over Full Range±1ºF (±0.5ºC)
    At Room Temperatures±1ºF (+0.4/-0.2ºC)
    Setpoint Range
    Heat Set Point38° to 89°F (3° to 32°C)
    Cool Set Point59° to 99°F (15° to 37°C), or 38° to 99°F (3° to 37°C) extended cool mode enabled
    Relay Rating
    1 Amp @ 40 Volts DC or 24 Volts AC (nominal)
    Environmental
    Temperature-10° to 110°F (-23° to 43°C)
    Humidity10% to 90% RH (non-condensing)
    Power Requirements
    24V0.24 Watts (10 mA) @ 24 Volts AC, supplied by heating or cooling system
    Battery(2) AA batteries required, estimated 1 year normal operation
    Housing
    Plastic, surface-mountable to the front of a horizontally oriented 1-gang electrical box
    Dimensions
    Height4.51 in (115 mm)
    Width5.50 in (141 mm)
    Depth1.02 in (26 mm)
    Weight
    6.7 oz (190 g)