Communications |
Ethernet | 10/100 Mbps, auto-switching, auto-negotiating, auto-discovery, full/half duplex, TCP/IP, UDP/IP, CIP, DHCP, SSL, SSH, SFTP (SSH File Transfer Protocol) |
USB Device | USB device port for computer console (setup) |
Audio |
Input Signal Types | Balanced or unbalanced analog line-level |
Output Signal Types | 4/8 Ohm, 70 or 100 Volt direct-coupled |
Operating Modes (Configurable via Avia Audio Tool software) | Mono: Each channel is configurable to operate independently from all other channels Stereo:The output channels are configurable to operate as a stereo pair with linked control settings Bridged: The output channels are configurable to operate as an 8 Ohm bridged mono output 4/8Ω Mode: Each channel is configurable for 4/8 Ohm “Lo-Z” output 70V/100V Mode: Each channel is configurable for 70/100 Volt “Hi-Z” output |
Output Power | 800 Watts per channel @ 4-8 Ohms or 70/100 Volts nominal; 1200 Watts per bridged pair of channels @ 8 Ohms |
Power Throttle | 800, 700, 600, 500, 400, 300, 250, 200, 150, 125, 100, 75, 50 Watts per channel |
Frequency Response | 20 Hz to 20 kHz ±0.5 dB at 1 Watt, 4-8 Ohms; 200 Hz to 20 kHz ±0.5 dB at 1 Watt, 70/100 Volts |
High Pass Filter | -3 dB @ 80 Hz, 12 dB per octave in 70V or 100V mode |
THD+N | <0.05% @ 1 kHz at 3 dB below clipping |
S/N Ratio | >103 dBA, 20 Hz to 20 kHz |
Channel Separation | >70 dB |
Input Sensitivity | 1.29 Vrms, +4 dBu (balanced) for full rated output power |
Fault Protection | Over Current: Protects each channel individually against an excessive speaker load or shorted speaker line DC Offset: Protects each channel and speaker line against DC voltages sensed at each output Over Temperature: Protects the amplifier power supply and each channel against overheating due to poor ventilation or excessive temperature Under Voltage: Protects the amplifier if the internal power supply voltage is below tolerance due to excessive output levels or insufficient line voltage; Note: All faults report to the control system, and indicate on the front panel and in the software tool. |
Output Relays | Disconnects the speaker line at each output under fault conditions, and during startup and shutdown |
Audio Ramp | Ramps each channel’s audio level to its last setting after the corresponding output relay has closed following startup or fault recovery; ramp time 130 milliseconds |
Connectors |
LINE INPUTS 1 & 2 | (2) 3-pin 3.5 mm detachable terminal blocks; Balanced line-level audio inputs; Maximum Input Level: 12.3 Vrms, +24 dBu; Input Impedance: 20k Ohms balanced |
SPEAKER OUTPUTS 1 & 2 | (2) 2-pin 7.62 mm reversed gender 20A detachable terminal blocks; Power amplifier outputs; Wire Size: Terminals accept up to 12 AWG (3.31 mm²); Note: Output is direct-coupled in all modes for all load types, not transformer isolated |
LAN | (1) 8-pin RJ45 female; 10Base-T/100Base-TX Ethernet LAN port |
100-240V~ 50/60Hz 4A-2A | (1) IEC 60320 C14 main power inlet; Mates with removable power cord (included) |
G | (1) 6-32 screw; Chassis ground lug |
COMPUTER (front) | (1) USB Type B female; USB computer console port (for setup only) |
Controls & Indicators |
PWR | (1) Bi-color green/amber LED, indicates operating power supplied from AC line power, amber indicates startup in progress, green indicates normal operation and a connection to the LAN, alternating green/amber indicates absence of a network connection |
RESET | (1) Recessed pushbutton, restores last saved settings |
STATUS, FAULT 1 & 2 | (2) Red LEDs, each indicates a fault on the corresponding channel with specifics indicated below |
STATUS, CURRENT 1 & 2 | (2) Blue LEDs, each indicates an over-current fault condition on the corresponding output |
STATUS, DC 1 & 2 | (2) Blue LEDs, each indicates a DC offset fault condition on the corresponding channel |
STATUS, THERM 1 & 2 | (2) Blue LEDs, each indicates an over-temperature fault condition on the corresponding channel |
STATUS, 70V-100V 1 & 2 | (2) Blue LEDs, each indicates the corresponding channel is configured for 70 Volt / 100 Volt operation |
VU 1 & 2 | (2) 5-segment LED bar graph audio level meters for each corresponding output; each contains (4) blue LEDs for -40dB, -30dB, -20dB, and -10dB, and (1) red LED for CLIP |
LINE INPUTS 1 & 2 (rear) | (2) Screwdriver-adjustable rotary controls, each adjusts the input attenuation level for the corresponding channel |
LAN (rear) | (2) LEDs, green LED indicates Ethernet link status, amber LED indicates Ethernet activity |
SETUP (rear) | (1) Red LED and (1) pushbutton for Ethernet setup, flashes while updating firmware |
Power Switch (rear) | (1) Rocker switch, turns main power on or off |
Circuit Breaker Reset (rear) | (1) Push button switch, resets 10A circuit breaker |
Power |
Main Power | 4-2 Amps @ 100-240 Volts AC, 50/60 Hz, 10 Amps max. |
Input Power | 300 Watts |
Power Consumption | 300 Watts, all channels driven at 1/8th output power; 50 Watts @ 120VAC / 60 Watts @ 230VAC, all channels idle |
Environmental |
Temperature | 41° to 104°F (5° to 40°C) |
Humidity | 10% to 90% RH (non-condensing) |
Heat Dissipation | 1025 BTU/hr, all channels driven at 1/8th output power; 240 BTU/hr, all channels idle |
Construction |
Chassis | Metal, variable-speed fan-cooled, vented sides |
Front Panel | Metal, black finish with polycarbonate label overlay |
Mounting | Freestanding or 1 RU 19-inch rack-mountable (front rack ears and rear support brackets included) |
Dimensions |
Height | 1.72 in (44 cm) |
Width | 17.28 in (439 mm); 19.00 in (483 mm) with rack ears |
Depth | 14.59 in (371 mm) |
Weight |
13.7 lb (6.2 kg) |
Compliance |
UL 60065, FCC Class A commercial use |