The Crestron® HZA‑PWR‑GFCI‑15A receptacles are designed for long-term reliability and ease of installation while meeting and exceeding the latest industry and UL performance standards. The receptacle is manufactured using durable, impact-resistant thermoplastic components to ensure that it is virtually unbreakable.
The HZA‑PWR‑GFCI‑15Areceptacle is NEC® compliant, UL Listed, and fully compliant with the latest UL943 Class A GFCI and UL498 requirements. Additionally, the HZA‑PWR‑GFCI‑15A incorporates a safety lock-out function to protect against miswired line-load connections and GFCI circuitry damage.
Power Requirements
125 VAC, 15 A;
2-pole, 3-wire grounding;
NEMA 5‑15R
Electrical Specifications
Dielectric Voltage Withstands 2,000 V per UL498
Current Interrupting Yes, at full rated current
Temperature Rise Max. 86ºF (30ºC) after 100 cycles of overload @ 150% of rated current (DC)
Trip Time 0.025 seconds (Class A)
Short-Circuit Testing Meets and exceeds 10 kA
Maximum Interrupting Capacity 20 A
Mechanical Specifications
Terminals Accepts 14–10 AWG wire;
Screw Terminals: Use 14–10 AWG wire
Wiring Type
Back wire
Connections
Line Contacts 0.03 in. thick 3-leaf brass
Terminal Screws #8-32 steel;
Hot: Brass plated;
Neutral: Nickel plated;
Ground: Zinc plated (green)
Terminal Clamps Brass-plated steel
Construction
Receptacle Top Housing: PC
Bottom Housing: PC
Strap: Galvanized steel
Faceplate Use a Horizon HZ-FP-G Series faceplate;
1-, 2-, 3-, and 4-gang faceplates are available1
Mounting Mounts in a 1-gang U.S. electrical box;
Gangable up to four units
Environmental
Temperature -31ºF to 151ºF (-35ºC to 66ºC)
Humidity 10% to 90% RH (noncondensing)
Flammability Meets UL94 requirements;
V0 rated
Dimensions
Height 4.13 in. (105 mm)
Width 1.80 in. (46 mm)
Depth 1.58 in. (40 mm);
Projects 0.41 in. (11 mm) from wall surface when installed
Compliance
cULus Listed to UL498 and UL943, file no. E60120, Meets all UL943 (GFCI), UL498 (Receptacles), UL498 and applicable CSA requirements, NOM certified.
The Crestron® HZA‑PWR‑GFCI‑15A receptacles are designed for long-term reliability and ease of installation while meeting and exceeding the latest industry and UL performance standards. The receptacle is manufactured using durable, impact-resistant thermoplastic components to ensure that it is virtually unbreakable.
The HZA‑PWR‑GFCI‑15A receptacle is NEC® compliant, UL Listed, and fully compliant with the latest UL943 Class A GFCI and UL498 requirements. Additionally, the HZA‑PWR‑GFCI‑15A incorporates a safety lock-out function to protect against miswired line-load connections and GFCI circuitry damage.
GFCI Code Compliant
Fully compliant with the latest NEC® and UL943 standards, Crestron GFCIs are tested to the highest standards and provide state-of-the-art, dependable electric shock protection. If the GFCI trips and is no longer able to safely provide power, the GFCI will not reset.
Periodic Self-Test
The HZA‑PWR‑GFCI‑15A performs a periodic self-test to ensure proper operation. If ground-fault protection is not detected, the device will trip, will not reset, and the status indicator light will glow amber.
Compliments Horizon™ Keypads
The design of the HZA‑PWR‑GFCI‑15A compliments Crestron's Horizon product line to create a consistent style across the room.
Customizable Horizon Faceplates
Crestron® HZ-FP-G Series Horizon faceplates1, 2 feature a distinctively clean appearance that can be customized to compliment any décor. Each faceplate includes color-matched top and bottom trim pieces in a choice of smooth or textured finish.3
The smooth trim provides a subtle contrast to the textured outlet face and side panels for an elegant two-tone look, while the textured trim matches the outlet face and sides for a more cohesive overall finish. The trim pieces may be swapped easily after installation without tools.
Custom trim pieces can be fabricated from any solid material, such as wood, metal, marble, engineered stone, or Corian®, to either match the wall surface or complement other design elements in the room.4 Paintable trim is also available separately to allow for a custom finish in any color you desire.
Key Features
GFCI duplex receptacle to provide ground fault protection
Tamper resistant shutters provide compliance with 2017 NEC® Article 406.12
Performs periodic self-tests to ensure the integrity of the GFCI protection
Meets and exceeds 10 kA short-circuit testing and UL® 2006 UL943 safety standards
Trip indicator LEDs for quick notification of a tripped or end of life condition
Line-side terminals are backed out and staked for fast installation
Horizontal test/reset button alignment provides larger unobstructed area
20 A feed-through rating offers full protection for downstream receptacles
Line/load miswiring protection prevents downstream power supply when wired incorrectly
Precision fit and finish
1-, 2-, 3-, or 4-gang installation using Crestron HZ‑FP‑G series faceplates
Contiguous surface when multi-ganged
Customizable faceplate trims