Features

  • One DAB-801 unit can provide N+1 instantaneous two-channel switchover redundancy for as many as eight amplifier output channels
  • Two DAB-801 units can be cascaded to provide two- or four-channel switchover redundancy for up to 16 amplifier output channels
  • Automatic detection and switchover between inputs from primary and backup I/O Frames, in case of failure upstream
  • Fault tolerant control and monitoring of each DAB-801 is available using simultaneous GPIO terminals connected to both primary and backup I/O Frames
  • Two additional non-networked analog “high line” level inputs provide emergency evacuation signal which can override all other input signals
  • QSC DataPort connectors and high-current terminal blocks for easy and reliable installation
  • Q-SYS technical support is available 24/7 worldwide
Price: CALL
    Quantity:
    Availability: In Stock
    Usually ships In 24 - 48 hours

    Item #: DAB-801

    Description

    DataPort Amplifier Backup Panel, 8 Channels, Provides amplifier redundancy when used with Q-SYS DataPort I/0, 4 RU

    Specifications

    Integrated System Platform

    DAB-801

    Q-Sys™ Amplifier and I/O Frame Backup Accessory

    Features

    • One DAB-801 unit can provide N+1 instantaneous 2-channel

    switchover redundancy for up to 8 amplifier output channels

    • Two DAB-801 units can be cascaded to provide 2 or

    4-channel switchover redundancy for up to 16 amplifier

    output channels

    • Automatic detection & switchover between inputs from

    Primary and Backup I/O Frames, in case of failure “upstream”

    • Fault tolerant control & monitoring of each DAB-801 is

    available using simultaneous GPIO terminals connected to

    both Primary and Backup I/O Frames

    • Two additional non-networked analog “high line” level inputs

    provide emergency evacuation signal which can override all

    other input signals

    • QSC Dataport Connectors and High Current Terminal Blocks

    for easy & reliable installation

    • Q-Sys technical support is available 24/7 - worldwide

    The purpose of the DataPort Amplifier

    Backup Panel is to provide redundancy,

    emergency paging, and other functionality

    required for many Life-Safety & Evacuation

    or mission-critical audio systems.

    The DAB-801 extends the Q-Sys fault-tolerant

    backup capability to include any QSC

    DataPort power amplifier and I/O Frames

    populated with Q-Sys DataPort cards. The

    DAB-801 provides the ability to add true N+1

    amplifier redundancy to any Q-Sys system,

    plus the ability to automatically switch

    amplifier input sources from a primary I/O

    Frame to a backup I/O Frame.

    A single DAB-801 supports four 2-channel

    primary amplifiers with one 2-channel backup

    amplifier, or two 4-channel primary amplifiers

    with one 4-channel backup amplifier. Two

    DAB- 801s can be stacked to provide double

    the primary amplifier redundancy.

    Two D-Sub 15 pin connections allow direct

    connection to a pair of Q-Sys I/O Frames for

    full control and monitoring of the DAB-801

    through the Q-Sys Designer software. All

    primary amplifiers are continuously

    monitored by Q-Sys along with the power-on

    status of the backup amplifier. Periodic full

    tests of the backup system can be

    programmed to ensure signal integrity and

    meet regulatory requirements.

    Additionally two analog “high line” level

    inputs allow for direct connection of a

    carbon-type microphone, or a linelevel

    pre-recorded message for emergency

    evacuation paging which can then override

    all other input signals. A normal low

    impedance paging microphone may also be

    connected with the addition of an external

    microphone preamp.

    Using these analog inputs, each DAB-801

    has two priority modes, Alarm and Page.

    The Alarm input overrides all other signals,

    and is used for major emergencies. The

    Page input overrides all signals except the

    Alarm input, and can be used for other

    announcements. These inputs can be

    assigned to any combination of amplifier

    channels, and can be activated with either a

    standard contact closure or +12VDC trigger

    voltage from the fire alarm panel.

    The DAB-801 is easily integrated into a

    Q-Sys based audio system. Mounted onto

    the rear of a rack, the DAB-801 minimizes

    rack space consumption. AC line

    connection is fast and easy with an IEC

    style quick-disconnect and locking bracket

    to ensure reliable AC mains connection. A

    one world power supply operates on

    100-240VAC, 50/60Hz.

    By using QSC standard HD-15 DataPort

    connectors and high current detachable

    terminal blocks, the DAB-801 provides an

    easy to install connector set.

    Various LED indicators alert the user to

    current panel status. The LEDs include an

    AC power indicator, I/O Frame power status

    indicators, amplifier power status indicators,

    I/O Frame failure indicators, and amplifier

    failure indicators.

    Each DAB-801 connects up to eight

    loudspeaker circuits, which may also be

    100V transformer isolated.

    Mic Pre

    Emergency Page Mic

    Pre-recorded Emergency Message

    PRIMARY Q-Sys I/O Frame

    BACKUP Dataport 2-CH Amplifier

    PRIMARY Dataport 2-CH Amplifiers

    GPIO

    2-CH

    DataPorts

    Loudspeaker circuits

    Q-Lan Network

    CLIP

    -10dB

    -20dB

    SIGNAL

    POWER

    BRIDGE PARALLEL

    CH1 CH2

    C X 3 0 2 V DIRECT 70V AMPLIFIER

    ON

    (35dB)

    2

    4

    6

    8 10 12

    14

    18

    24

    0

    ATTEN

    24

    18

    14

    12 10 8

    6

    4

    2

    (35dB) 0

    ATTEN

    DAB

    801

    CLIP

    -10dB

    -20dB

    SIGNAL

    POWER

    BRIDGE PARALLEL

    CH1 CH2

    C X 3 0 2 V DIRECT 70V AMPLIFIER

    ON

    (35dB)

    2

    4

    6

    8 10 12

    14

    18

    24

    0

    ATTEN

    24

    18

    14

    12 10 8

    6

    4

    2

    (35dB) 0

    ATTEN

    CLIP

    -10dB

    -20dB

    SIGNAL

    POWER

    BRIDGE PARALLEL

    CH1 CH2

    C X 3 0 2 V DIRECT 70V AMPLIFIER

    ON

    (35dB)

    2

    4

    6

    8 10 12

    14

    18

    24

    0

    ATTEN

    24

    18

    14

    12 10 8

    6

    4

    2

    (35dB) 0

    ATTEN

    CLIP

    -10dB

    -20dB

    SIGNAL

    POWER

    BRIDGE PARALLEL

    CH1 CH2

    C X 3 0 2 V DIRECT 70V AMPLIFIER

    ON

    (35dB)

    2

    4

    6

    8 10 12

    14

    18

    24

    0

    ATTEN

    24

    18

    14

    12 10 8

    6

    4

    2

    (35dB) 0

    ATTEN

    CLIP

    -10dB

    -20dB

    SIGNAL

    POWER

    BRIDGE PARALLEL

    CH1 CH2

    C X 3 0 2 V DIRECT 70V AMPLIFIER

    ON

    (35dB)

    2

    4

    6

    8 10 12

    14

    18

    24

    0

    ATTEN

    24

    18

    14

    12 10 8

    6

    4

    2

    (35dB) 0

    ATTEN

    Mic Pre

    Emergency Page Mic

    Pre-recorded Emergency Message

    PRIMARY Q-Sys I/O Frame

    BACKUP Dataport 4-CH Amplifier

    PRIMARY Dataport 4-CH Amplifiers

    GPIO

    2-CH

    DataPorts

    Loudspeaker circuits

    Q-Lan Network

    2-CH

    DataPorts

    BACKUP Q-Sys I/O Frame

    CLIP

    -10dB

    -20dB

    SIGNAL

    POWER

    BRIDGE PARALLEL

    CH1 CH2

    C X 3 0 2 V DIRECT 70V AMPLIFIER

    ON

    (35dB)

    2

    4

    6

    8 10 12

    14

    18

    24

    0

    ATTEN

    24

    18

    14

    12 10 8

    6

    4

    2

    (35dB) 0

    ATTEN

    DAB

    801

    ON

    PROFESSIONAL AMPLIFIER 2

    4

    6

    8 10 12

    14

    18

    24

    ATTEN

    O0 0

    CX404

    (31dB)

    24

    (31dB)

    ATTEN

    O0 0

    2

    14

    18

    12 10

    6

    8

    24

    (31dB)

    ATTEN

    O0 0

    2

    14

    18

    12 10

    6

    8

    24

    (31dB)

    ATTEN

    O0 0

    2

    14

    18

    12 10

    6

    8

    CLIP

    -10dB

    -20dB

    SIG

    BRDG

    PAR

    POWER

    1&2 3&4

    SIG

    -20dB

    -10dB

    CH1 2 3 CLIP CH4

    ON

    PROFESSIONAL AMPLIFIER 2

    4

    6

    8 10 12

    14

    18

    24

    ATTEN

    O0 0

    CX404

    (31dB)

    24

    (31dB)

    ATTEN

    O0 0

    2

    14

    18

    12 10

    6

    8

    24

    (31dB)

    ATTEN

    O0 0

    2

    14

    18

    12 10

    6

    8

    24

    (31dB)

    ATTEN

    O0 0

    2

    14

    18

    12 10

    6

    8

    CLIP

    -10dB

    -20dB

    SIG

    BRDG

    PAR

    POWER

    1&2 3&4

    SIG

    -20dB

    -10dB

    CH1 2 3 CLIP CH4

    2-CH DataPort cable / bi-directional

    Speaker Lines / Hi-Z or Low-Z

    GPI/O Cable

    Q-Sys LAN

    Audio Cable

    Legend:

    Single I/O Frame (pictured here with 2-Channel amplifiers)

    Backup I/O Frame (pictured here with 4-Channel amplifiers)

    Common DAB-801 Configurations

    DAB

    801

    DAB

    801

    CLIP

    -10dB

    -20dB

    SIGNAL

    POWER

    BRIDGE PARALLEL

    CH1 CH2

    C X 3 0 2 V DIRECT 70V AMPLIFIER

    ON

    (35dB)

    2

    4

    6

    8 10 12

    14

    18

    24

    0

    ATTEN

    24

    18

    14

    12 10 8

    6

    4

    2

    (35dB) 0

    ATTEN

    CLIP

    -10dB

    -20dB

    SIGNAL

    POWER

    BRIDGE PARALLEL

    CH1 CH2

    C X 3 0 2 V DIRECT 70V AMPLIFIER

    ON

    (35dB)

    2

    4

    6

    8 10 12

    14

    18

    24

    0

    ATTEN

    24

    18

    14

    12 10 8

    6

    4

    2

    (35dB) 0

    ATTEN

    CLIP

    -10dB

    -20dB

    SIGNAL

    POWER

    BRIDGE PARALLEL

    CH1 CH2

    C X 3 0 2 V DIRECT 70V AMPLIFIER

    ON

    (35dB)

    2

    4

    6

    8 10 12

    14

    18

    24

    0

    ATTEN

    24

    18

    14

    12 10 8

    6

    4

    2

    (35dB) 0

    ATTEN

    CLIP

    -10dB

    -20dB

    SIGNAL

    POWER

    BRIDGE PARALLEL

    CH1 CH2

    C X 3 0 2 V DIRECT 70V AMPLIFIER

    ON

    (35dB)

    2

    4

    6

    8 10 12

    14

    18

    24

    0

    ATTEN

    24

    18

    14

    12 10 8

    6

    4

    2

    (35dB) 0

    ATTEN

    BACKUP Q-Sys I/O Frame

    GPIO

    2-CH

    DataPorts

    Loudspeaker circuits

    Q-Lan Network

    GPIO

    2-CH

    DataPorts

    Loudspeaker circuits

    PRIMARY Q-Sys I/O Frame

    Control

    Extension

    Bus

    Speaker

    Extension

    Bus

    PRIMARY Dataport 2-CH Amplifiers

    CLIP

    -10dB

    -20dB

    SIGNAL

    POWER

    BRIDGE PARALLEL

    CH1 CH2

    C X 3 0 2 V DIRECT 70V AMPLIFIER

    ON

    (35dB)

    2

    4

    6

    8 10 12

    14

    18

    24

    0

    ATTEN

    24

    18

    14

    12 10 8

    6

    4

    2

    (35dB) 0

    ATTEN

    BACKUP Dataport 2-CH Amplifier

    PRIMARY Dataport 2-CH Amplifiers

    CLIP

    -10dB

    -20dB

    SIGNAL

    POWER

    BRIDGE PARALLEL

    CH1 CH2

    C X 3 0 2 V DIRECT 70V AMPLIFIER

    ON

    (35dB)

    2

    4

    6

    8 10 12

    14

    18

    24

    0

    ATTEN

    24

    18

    14

    12 10 8

    6

    4

    2

    (35dB) 0

    ATTEN

    CLIP

    -10dB

    -20dB

    SIGNAL

    POWER

    BRIDGE PARALLEL

    CH1 CH2

    C X 3 0 2 V DIRECT 70V AMPLIFIER

    ON

    (35dB)

    2

    4

    6

    8 10 12

    14

    18

    24

    0

    ATTEN

    24

    18

    14

    12 10 8

    6

    4

    2

    (35dB) 0

    ATTEN

    CLIP

    -10dB

    -20dB

    SIGNAL

    POWER

    BRIDGE PARALLEL

    CH1 CH2

    C X 3 0 2 V DIRECT 70V AMPLIFIER

    ON

    (35dB)

    2

    4

    6

    8 10 12

    14

    18

    24

    0

    ATTEN

    24

    18

    14

    12 10 8

    6

    4

    2

    (35dB) 0

    ATTEN

    CLIP

    -10dB

    -20dB

    SIGNAL

    POWER

    BRIDGE PARALLEL

    CH1 CH2

    C X 3 0 2 V DIRECT 70V AMPLIFIER

    ON

    (35dB)

    2

    4

    6

    8 10 12

    14

    18

    24

    0

    ATTEN

    24

    18

    14

    12 10 8

    6

    4

    2

    (35dB) 0

    ATTEN

    2-CH DataPort cable / bi-directional

    Speaker Lines / Hi-Z or Low-Z

    GPI/O Cable

    Q-Sys LAN

    Audio Cable

    Legend:

    Two linked DAB-801’s using Extension Bus

    (pictured here with 2-Channel amplifiers)

    Specifications

    Q-Sys DAB-801 Spec Sheet - 05/09/11

    1675 MacArthur Boulevard • Costa Mesa, CA 92626 • Ph: 800/854-4079 or 714/957-7100 • Fax: 714/754-6174 qscaudio.com

    ©2011 QSC Audio Products, LLC. All rights reserved. QSC and the QSC logo are registered trademarks of QSC Audio Products, LLC in the U.S. Patent and Trademark office and

    other countries. Q-Sys is a trademark of QSC Audio Products, LLC.

    please recycle

    DAB-801

    Connectors

    Input

    Output

    Other

    6 Position “Euro” or “Phoenix” type, QSC DataPort (HD-15), QSC GPIO (DB-15).

    QSC DataPort (HD-15), 8 position high current “Euro” or “Phoenix” type.

    Control Extension Bus (DB-37), IEC type AC Inlet.

    Controls Page Assignment: 8 position “dip” type toggle switch

    Page/Alarm Inputs Balanced 5k ohm, 3 Vrms.

    LED Indicators Power (blue, 1 each).

    NORMAL (green, 8 each, 1 per primary DP).

    FAULT (red, 8 each, 1 per primary DP).

    BACKUP ACTIVE (yellow, 6 each, 1 per backup DP)

    Maximum Amplifier Ratings 1200 W per channel

    Power Requirements 100 – 240 VAC, 50 – 60 Hz, 12 W max.

    Operating Temperature (Tma) 0˚C – 40˚C non condensing

    Dimensions (HWD) 7" (17.8 cm) 4 RU x 19" (48.3 cm) rack mounting x 2" (5.1 cm)

    Weight (net/shipping) 7.8 lb (3.5 kg) / 10.8 lb (5kg)

    17.14±0.0

    [435.3±0.3]

    FRONT VIEW

    REAR VIEW

    SCALE: 1:1

    6.96±0.0

    [176.8±0.3]